Cooling Water Treatment Chemical Solenoid Metering Pump 

  产品分类 : 機械與設備->整廠設備輸出->大底整廠設備及規劃

     
Cooling Water Treatment Chemical Solenoid Metering Pump
         

  产品规格
 
Model No:    JCMB55-25/2.0
  Country  CN
  Brand  AILIPU
  Packing  Strong carton packing suitable for the long distance transportation.
  Minimum Order  10
  Payment Term  L/C,T/T

 

  产品描述
   
  <div id="0m566" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-uj2j7" style="padding:8px 0px 4px 8px;color:#4D6599;font-size:22px;background-color:#C5CCDE;">
Product Description
</div>
</div>
<p style="font-size:13.3333px;">
<b>1. High Speed OperationL:&nbsp;</b><span style="font-size:13.3333px;">Up to 400 strokes per minute</span>
</p>
<p style="font-size:13.3333px;">
<b>2. Compact Size</b>
</p>
<p style="font-size:13.3333px;">
<b>3. Long Lasting Diaphragm:</b><span style="font-size:13.3333px;">&nbsp;The life of the diaphragm is over 5 years, which 5 times as national standard GB/T7782-2008</span>
</p>
<p style="font-size:13.3333px;">
<b>4. Strong Power Supply Compatibility:</b><span style="font-size:13.3333px;">&nbsp;smooth working stability in AC100-240V, and suitable for 50-60Hz range</span>
</p>
<p style="font-size:13.3333px;">
<b>5. High Protection Level</b>
</p>
<p style="font-size:13.3333px;">
<b>6. Double Valve Ball Structure</b>
</p>
<p style="font-size:13.3333px;">
<b><br />
</b>
</p>
<p>
<br />
</p>
<p>
<b>JCMB45 Model</b>
</p>
<p>
<br />
</p>
<div style="vertical-align:top;margin-left:-4px;">
<p>
<table class="MsoNormalTable" border="1" cellspacing="0" cellpadding="0" width="606" style="width:454.35pt;">
<tbody>
<tr>
<td width="105">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Model</span>
</p>
</td>
<td width="76">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Max. Flow</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Max. Pressure</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Pipe Dia. (mm)</span>
</p>
</td>
<td width="123">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Suction Pipe Material</span>
</p>
</td>
<td width="132">
<p class="MsoNormal">
<span style="font-size:8pt;font-family:'';">Discharge Pipe Material</span>
</p>
</td>
</tr>
<tr>
<td width="105">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">JCMB45–3/15</span>
</p>
</td>
<td width="76">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">3.0 L/H</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">15bar</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">In5.5 Out 9.5</span>
</p>
</td>
<td width="123">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PVC</span>
</p>
</td>
<td width="132" valign="top">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PE</span>
</p>
</td>
</tr>
<tr>
<td width="105">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">JCMB45–5/10</span>
</p>
</td>
<td width="76">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">5.0 L/H</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">10bar</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">In5.5 Out 9.5</span>
</p>
</td>
<td width="123">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PVC</span>
</p>
</td>
<td width="132" valign="top">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PE</span>
</p>
</td>
</tr>
<tr>
<td width="105">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">JCMB45–10/5</span>
</p>
</td>
<td width="76">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">10 L/H</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">5bar</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">In5.5 Out 9.5</span>
</p>
</td>
<td width="123">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PVC</span>
</p>
</td>
<td width="132" valign="top">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PE</span><b>&nbsp;</b>
</p>
</td>
</tr>
</tbody>
</table>
</p>
<p>
<br />
</p>
<p>
<b>JCMB55 Model</b>
</p>
<table class="MsoNormalTable" border="1" cellspacing="0" cellpadding="0" width="630" style="width:472.5pt;">
<tbody>
<tr>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Model</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Max. Flow</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Max. Pressure</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Pipe Dia. (mm)</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Suction Pipe Material</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Discharge Pipe Material</span>
</p>
</td>
</tr>
<tr>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">JCMB55–15/3.2</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">15 L/H</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">3.2bar</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">In6.5 Out 9.5</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PVC</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PE</span>
</p>
</td>
</tr>
<tr>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">JCMB55–20/2.5</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">20 L/H</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">2.5bar</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">In6.5 Out 9.5</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PVC</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PE</span>
</p>
</td>
</tr>
<tr>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">JCMB55–25/2.0</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">25 L/H</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">2.0bar</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">In6.5 Out 9.5</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PVC</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PE</span>
</p>
</td>
</tr>
</tbody>
</table>
<p class="MsoNormal">
&nbsp;
</p>
<p>
<br />
</p>
<p>
<br />
</p>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="kpsek" style="vertical-align:top;">
<img src="http://i.bosscdn.com/uploads/12/54/cf/f1396c2fa3c03b2d0ad691c552.png" width="334" height="319" title="Solenoid pump outline dimention" alt="Solenoid pump outline dimention" /><img src="http://i.bosscdn.com/uploads/2e/08/3d/dfe342c4fc8412a9cde27828f4.png" width="371" height="340" title="Solenoid pump " alt="Solenoid pump " />
</div>
</div>
<p>
<br />
</p>
<div style="font-size:13.3333px;vertical-align:top;">
<div id="kmoa3" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-k4anm" style="padding:8px 0px 4px 8px;color:#4D6599;font-size:22px;background-color:#C5CCDE;">
JCMB Series
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="4tie7" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/b0/ab/13/329d8641bbdb9fd10530ef94e8.png" width="218" height="213" title="Solenoid metering pump manual control" alt="Solenoid metering pump manual control" />
</div>
<div style="vertical-align:top;">
<div id="0wlnb" style="vertical-align:top;">
<h3 style="font-size:16px;color:#333333;">
JCMB-S
</h3>
</div>
<div id="femn0" style="vertical-align:top;">
<p>
1. Manual &nbsp;flow&nbsp;adjusting&nbsp;
</p>
<p>
2. Pump On/Off indicator
</p>
<p>
3. Displayable frequency percentage
</p>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="emv3o" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/ad/84/28/d5a06bcffafeacad193b2a0c1b.png" width="198" height="210" title="Solenoid metering pump Auto-Adjust (Digital impulse signal control)" alt="Solenoid metering pump Auto-Adjust (Digital impulse signal control)" />
</div>
<div style="vertical-align:top;">
<div id="qri9x" style="vertical-align:top;">
<h3 style="font-size:16px;color:#333333;">
JCMB-C Auto-Adjust (Digital impulse signal control)
</h3>
</div>
<div id="b8b7t" style="vertical-align:top;">
<p>
<span style="line-height:1.5;"></span>
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
Two control modes available:
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
1. Manual
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
2. Auto: controlled by the signal received&nbsp;<span style="line-height:1.5;">&nbsp;(Digital pulse signal)&nbsp;</span>
</p>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="sb56z" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/f6/e4/43/4a67b2e29d7cc9ea21da0e8390.png" width="198" height="213" title="Solenoid metering pump Auto-Adjust (4-20mA electric current signal control with Rs485 communication interface)" alt="Solenoid metering pump Auto-Adjust (4-20mA electric current signal control with Rs485 communication interface)" />
</div>
<div style="vertical-align:top;">
<div id="4wpaw" style="vertical-align:top;">
<h3 style="font-size:16px;color:#333333;">
JCMB-H Auto-Adjust (4-20mA electric current signal control)
</h3>
</div>
<div id="dl8sl" style="vertical-align:top;">
<p class="MsoNormal" align="left" style="vertical-align:top;">
Two control modes available:
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
1. Manual
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
2. Auto: controlled by the signal received&nbsp;<span style="line-height:1.5;">&nbsp;(4-20mA electric current signal)&nbsp;</span>
</p>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="7qkbu" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/ca/84/f1/6c6de1b00ab4e61c2f98dcb72d.png" width="198" height="223" title="Solenoid metering pump Auto-Adjust (Digital impulse signal control feedback)" alt="Solenoid metering pump Auto-Adjust (Digital impulse signal control feedback)" />
</div>
<div style="vertical-align:top;">
<div id="iwxjz" style="vertical-align:top;">
<h3 style="font-size:16px;color:#333333;">
JCMB-F Auto-Adjust (Digital impulse signal control feedback)
</h3>
</div>
<div id="4kve8" style="vertical-align:top;">
<p class="MsoNormal" align="left" style="vertical-align:top;">
Two control modes available:
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
1. Manual
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
2. Auto: controlled by the signal received&nbsp;<span style="line-height:1.5;">(Digital pulse signal ) and feedback operating signal for remote control.</span>
</p>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="fnd6t" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/ca/84/f1/6c6de1b00ab4e61c2f98dcb72d.png" width="198" height="227" title="Solenoid metering pump Auto-Adjust (Digital impulse signal control feedback with Rs485 communication interface)" alt="Solenoid metering pump Auto-Adjust (Digital impulse signal control feedback with Rs485 communication interface)" />
</div>
<div style="vertical-align:top;">
<div id="r5xdx" style="vertical-align:top;">
<h3 style="font-size:16px;color:#333333;">
JCMB-CR Auto-Adjust (Digital impulse signal control feedback with Rs485 communication interface)
</h3>
</div>
<div id="vniw8" style="vertical-align:top;">
<p class="MsoNormal" align="left" style="vertical-align:top;">
Two control modes available:
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
1. Manual
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
2. Auto: controlled by the signal received&nbsp;<span style="line-height:1.5;">(Digital pulse signal ) and feedback operating signal for remote control&nbsp;</span><span style="line-height:1.5;">with Rs485 communication interface by MODBUS protocol.&nbsp;</span>
</p>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="wqhfh" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/f6/e4/43/4a67b2e29d7cc9ea21da0e8390.png" width="198" height="239" title="Solenoid metering pump Auto-Adjust (4-20mA electric current signal control with Rs485 communication interface)" alt="Solenoid metering pump Auto-Adjust (4-20mA electric current signal control with Rs485 communication interface)" />
</div>
<div style="vertical-align:top;">
<div id="3q6rp" style="vertical-align:top;">
<h3 style="font-size:16px;color:#333333;">
JCMB-H Auto-Adjust (4-20mA electric current signal control with Rs485 communication interface)
</h3>
</div>
<div id="wtypr" style="vertical-align:top;">
<p class="MsoNormal" align="left" style="vertical-align:top;">
Two control modes available:
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
1. Manual
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
2. Auto: controlled by the signal received (4-20mA electric current signal) with Rs485 communication interface: using MODBUS protocol.&nbsp;
</p>
</div>
</div>
</div>
</div>
<div style="font-size:13.3333px;vertical-align:top;">
<div id="3xpeo" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-nrm29" style="padding:8px 0px 4px 8px;color:#4D6599;font-size:22px;background-color:#C5CCDE;">
Our Certifications
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="gjkj5" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/87/a4/cd/c38cdfb091fd015823217cce1d.jpg" width="146" height="207" title="ISO14001" alt="ISO14001" /><img src="http://i.bosscdn.com/product/51/8f/2b/c7315ca00623eaef75d1a2c084.jpg" width="148" height="208" title="ISO9001" alt="ISO9001" /><img src="http://i.bosscdn.com/product/36/c6/51/7f000be59064c20313593419fe.jpg" width="148" height="207" title="CE1" alt="CE1" /><img src="http://i.bosscdn.com/product/0a/90/af/83c57b8593eb3b7e52e84784ae.jpg" width="146" height="207" title="CE2" alt="CE2" />
</div>
</div>
</div>alipu.com

  其他类似产品
 
High Pressure Hydraulic Diaphragm Injection Pump

High Pressure Hydraulic Diaphragm Injection Pump
Phosphate Injection Diaphragm Dosing Pump

Phosphate Injection Diaphragm Dosing Pump
Water Plant Chemical Diaphragm Dosing pump

Water Plant Chemical Diaphragm Dosing pump
Solenoid Diaphragm Dosing Pump

Solenoid Diaphragm Dosing Pump
 
   


[ 返回产品型录 ]

Commerce 会员:
请登录您的帐号跟口令,系统将为您填入您的相关资料
 
 
帐号:
口令:
记住我的帐号
 
 
填写下列表格并寄送询问函.所有的询问信函将会自动寄发给你想联络的公司
主題
內容 ( 请勿输入公司名称、Email、电话、传真、网址 )
   

 


公司简介:

* 公司名称
*E-mail
*国家
*联络人
网址
*电话
- -
传真
- -
*邮递区号
*城市
*街道地址
*企业形态
批发商   出口商 进口商 制造商
大盘商 零售商  代理商 Retrofitter 使用者
其他, 请详细说明:
*安全口令
请输入所显示的安全口令


网站导览 l 隐私权政策 l 服务团队 l 合作提案 l 联络我们 l 帮帮我 l 广告刊登l  B2B商业伙伴
    .