登录 添加会员 求助
 
Zhejiang Ailipu Technology Co., LTD.
 
 
Recommended Results 
 
Remote Controlable Diaphragm Metering Pump 

  产品分类 : 機械與設備->整廠設備輸出->大底整廠設備及規劃

     
Remote Controlable Diaphragm Metering Pump
         

  产品规格
 
Model No:    JXM-AD
  Country  CN
  Brand  AILIPU
  Packing  Strong Carton packing suitable for the sea transportation
  Minimum Order  10
  Payment Term  L/C,T/T

 

  产品描述
   
  <div>
</div>
<div>
<div style="vertical-align:top;">
<div id="6gpjx" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-liujl" style="padding:8px 0 4px 8px;color:#4D6599;background-color:#C5CCDE;font-size:22px;">
Product Description
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="cfau2" style="vertical-align:top;">
<p>
The JXM-A series of dosing pumps offer the high performance with the capacity up to 1200L/H and with outstanding values for pressure applications up to 12 Bar. This series dosing pump is designed for durability and cost effectiveness, which is welcome to be unsed in lots of lines, such as the water treatment, chemical, power, food and beverage, paper, textile etc.
</p>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="wb388" style="vertical-align:top;">
<table class="MsoNormalTable" style="width:538pt;">
<tbody>
<tr>
<td width="111" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center" style="text-align:center;">
<span style="font-family:Calibri;font-size:11pt;"></span>
</p>
</td>
<td width="96" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="right">
l/h
</p>
</td>
<td width="103" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="right">
&nbsp;&nbsp;(Mpa)
</p>
</td>
<td width="70" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
&nbsp;
</p>
</td>
<td width="79" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="right">
(mm)
</p>
</td>
<td width="99" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="right">
(mm)
</p>
</td>
<td width="88" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="right">
(KW)
</p>
</td>
<td width="67" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="right">
(KG)
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 2.25/1.2
</p>
</td>
<td width="96" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
2.25
</p>
</td>
<td width="103" valign="center" rowspan="5" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
1.2
</p>
</td>
<td width="70" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
36
</p>
</td>
<td width="79" valign="center" rowspan="3" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
1.2
</p>
</td>
<td width="99" valign="center" rowspan="3" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
DN8
</p>
</td>
<td width="88" valign="center" rowspan="9" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
0.37KW
</p>
</td>
<td width="67" valign="center" rowspan="12" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
18
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 4.5/1.2
</p>
</td>
<td width="96" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
4.5
</p>
</td>
<td width="70" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
&nbsp;
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 9/1.2
</p>
</td>
<td width="96" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
9
</p>
</td>
<td width="70" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
144
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 22/1.2
</p>
</td>
<td width="96" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
22
</p>
</td>
<td width="70" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
72
</p>
</td>
<td width="79" valign="center" rowspan="2" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
4
</p>
</td>
<td width="99" valign="center" rowspan="5" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
DN15
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 44/1.2
</p>
</td>
<td width="96" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
44
</p>
</td>
<td width="70" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
144
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 85/1.0
</p>
</td>
<td width="96" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
85
</p>
</td>
<td width="103" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
1
</p>
</td>
<td width="70" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
72
</p>
</td>
<td width="79" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
6
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 120/0.7
</p>
</td>
<td width="96" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
120
</p>
</td>
<td width="103" valign="center" rowspan="3" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
0.7
</p>
</td>
<td width="70" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
72
</p>
</td>
<td width="79" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
8
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 170/0.7
</p>
</td>
<td width="96" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
170
</p>
</td>
<td width="70" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
144
</p>
</td>
<td width="79" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
6
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 240/0.7
</p>
</td>
<td width="96" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
240
</p>
</td>
<td width="70" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
144
</p>
</td>
<td width="79" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
8
</p>
</td>
<td width="99" valign="center" rowspan="4" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
DN25
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 315/0.5
</p>
</td>
<td width="96" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
315
</p>
</td>
<td width="103" valign="center" rowspan="3" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
0.5
</p>
</td>
<td width="70" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
144
</p>
</td>
<td width="79" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
8
</p>
</td>
<td width="88" valign="center" rowspan="3" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
0.55KW
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 400/0.5
</p>
</td>
<td width="96" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
400
</p>
</td>
<td width="70" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
144
</p>
</td>
<td width="79" valign="center" rowspan="2" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
10
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 500/0.5
</p>
</td>
<td width="96" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
500
</p>
</td>
<td width="70" valign="center" style="border:1.0000pt solid #000000;">
<p class="MsoNormal" align="center">
180
</p>
</td>
</tr>
</tbody>
</table>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="1giy1" style="vertical-align:top;">
<div>
<img src="http://i.bosscdn.com/uploads/19/8f/ee/7e8dabfb5e04b997110ef96b44.jpg" width="750" height="416" title="Metering pump drawing " alt="Metering pump drawing " />
</div>
</div>
</div>
</div>
<div style="vertical-align:top;">
<div id="ydkl2" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-lnyob" style="padding:8px 0 4px 8px;color:#4D6599;background-color:#C5CCDE;font-size:22px;">
Products Show
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="1kc6m" style="vertical-align:top;">
<div>
<img src="http://i.bosscdn.com/uploads/2b/9f/be/4607d2041caecc53be3c081e3d.jpg" width="750" height="765" title="Digital controller metering pump " alt="Digital controller metering pump " />
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div style="vertical-align:top;">
<div id="sjpin" style="vertical-align:top;">
<h3 style="font-size:16px;font-weight:bold;color:#333;">
Technical Specifications
</h3>
</div>
<div id="ihnx8" style="vertical-align:top;">
<p>
* Flow rates up to 500L/H, pressure up to 12Bar
</p>
<p>
* Adjustment of flowrate from 0% - 100% while running or stopped
</p>
<p>
* Accuracy +/- 2% of 100% rated flow
</p>
<p>
* Mechanically actuated PTFE diaphragm
</p>
<p>
* Maximum temperature of pumped fluid: +10℃ - 40℃
</p>
<p>
* Maximum suction up to 2M
</p>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div style="vertical-align:top;">
<div id="wa53k" style="vertical-align:top;">
<h3 style="font-size:16px;font-weight:bold;color:#333;">
Features &amp; Benefits&nbsp;
</h3>
</div>
<div id="vq71y" style="vertical-align:top;">
<p>
* Mechanical actuated diagragm design, easy operation and with the convenience maintanence
</p>
<p>
* Changeable eccentric drive, no leakage with security delivery
</p>
<p>
* Rugged construction designed to withstand tough environments
</p>
<p>
* Oil bath lubrication for all of drive components
</p>
<p>
* Various pump head material (PVC, PVDF, SS304, SS316 etc.) to meet different solution needs
</p>
<p>
* Available with the manual control and digital control model&nbsp;
</p>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div style="vertical-align:top;">
<div id="e7jqj" style="vertical-align:top;">
<h3 style="font-size:16px;font-weight:bold;color:#333;">
Control
</h3>
</div>
<div id="o0ofa" style="vertical-align:top;">
<p>
* Stroke actuator with 4-20mA signal<br />
* Digital controller with 4-20mA signal&nbsp;
</p>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div style="vertical-align:top;">
<div id="a1qyh" style="vertical-align:top;">
<h3 style="font-size:16px;font-weight:bold;color:#333;">
Others
</h3>
</div>
<div id="lru7a" style="vertical-align:top;">
<p>
* The Pump can be used to deliver the solution which is high-viscosity, corrosive and dangerous
</p>
<p>
* Diaphragm rupture detection system (Double diaphragm) is optional.
</p>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="ujhii" style="vertical-align:top;">
<div>
<img src="http://i.bosscdn.com/uploads/81/b6/1d/1f881d857982d9c04485b81e58.jpg" width="301" height="329" title="Digital controller for metering pump" alt="Digital controller for metering pump" /><img src="http://i.bosscdn.com/uploads/0b/3e/90/aaf5955f847171f76d708629e5.jpg" width="334" height="336" title="Digital controller for metering pump" alt="Digital controller for metering pump" />
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div style="vertical-align:top;">
<div id="f344g" style="vertical-align:top;">
<h3 style="font-size:16px;font-weight:bold;color:#333;">
Digital Controller: Technical Parameter
</h3>
</div>
<div id="sw1mp" style="vertical-align:top;">
<p>
* Ambient Temp: 0 --- 50℃<br />
* Input Control Signal (standard): 4 ---20 mA<br />
* Power Supply (standard): 220V +/- 10%, 1 phase, 50Hz<br />
* Highest loaded power: 0.55KW<br />
* Remote ON/OFF: Dry Contact switch<br />
* Alarm - Output: 220V switch<br />
* Signal Input:<br />
&nbsp; &nbsp; &nbsp;A: 4 --- 20mA simulation signal<br />
&nbsp; &nbsp; &nbsp;B: Hall signal: Use Non-touching Hall signal to change pulse into flow signal <br />
&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Wave: Rectangle<br />
&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Extent: Over 3.5V<br />
&nbsp; &nbsp; &nbsp;Output Voltage: +/- 12VDC
</p>
</div>
</div>
</div>
</div>
<div style="vertical-align:top;">
<div id="m84r7" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-cazm3" style="padding:8px 0 4px 8px;color:#4D6599;background-color:#C5CCDE;font-size:22px;">
Our Company
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div style="vertical-align:top;">
<div style="vertical-align:top;margin-left:-4px;">
<div id="ilc08" style="vertical-align:top;">
<div>
<img src="http://i.bosscdn.com/uploads/f7/f5/a8/cbbc2cfe5314e68f6f6dc66786.jpg" width="371" height="278" title="Metering pump workshop" alt="Metering pump workshop" /><img src="http://i.bosscdn.com/uploads/bd/88/da/b2a030b5d4aabc778c1e948ce4.jpg" width="371" height="278" title="Metering pump workshop" alt="Metering pump workshop" />
</div>
</div>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div style="vertical-align:top;">
<div style="vertical-align:top;margin-left:-4px;">
<div id="fiifm" style="vertical-align:top;">
<div>
<img src="http://i.bosscdn.com/uploads/d8/ff/ad/2111b63b847d393510564e9bc8.jpg" width="371" height="255" title="Metering pump workshop" alt="Metering pump workshop" /><img src="http://i.bosscdn.com/uploads/fc/77/4e/c9fbca95814980524517bcac97.jpg" width="371" height="247" title="Metering pump workshop" alt="Metering pump workshop" />
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div style="vertical-align:top;">
<div id="mlky2" style="vertical-align:top;">
<p>
<br />
</p>
</div>
</div>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="ktt3o" style="vertical-align:top;">
<div>
<img src="http://i.bosscdn.com/uploads/9b/4a/67/1c8b5e6736e9819898a8109b57.jpg" width="750" height="515" title="Metering pump manufacturer" alt="Metering pump manufacturer" />
</div>
</div>
</div>
</div>
<div style="vertical-align:top;">
<div id="gwqfv" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-vjvjd" style="padding:8px 0 4px 8px;color:#4D6599;background-color:#C5CCDE;font-size:22px;">
Our Certifications
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="s1eok" style="vertical-align:top;">
<div>
<img src="http://i.bosscdn.com/uploads/f9/21/56/8a1e04f95bcaefe55ac08e1317.jpg" width="148" height="211" title="Metering pump certificates" alt="Metering pump certificates" /><img src="http://i.bosscdn.com/uploads/bb/80/66/4361fdb18a55d2409b5eb16358.jpg" width="148" height="203" title="Metering pump certificates" alt="Metering pump certificates" /><img src="http://i.bosscdn.com/uploads/1c/6e/bd/b70b171b4025476974ff8d81b1.jpg" width="164" height="232" title="Metering pump certificates ISO 14001" alt="Metering pump certificates ISO 14001" /><img src="http://i.bosscdn.com/uploads/8e/fc/a7/f2cf9e9b0e0f9ef929eaa9bf1f.jpg" width="164" height="231" title="Metering pump certificates ISO9001" alt="Metering pump certificates ISO9001" />
</div>
</div>
</div>
</div>
</div>
<div>
</div>alipu.com

  其他类似产品
 
Swimming Pool Chlorine Solenoid Dosing Pump

Swimming Pool Chlorine Solenoid Dosing Pump
Chemical Micro Electric Diaphragm Dosing Pump

Chemical Micro Electric Diaphragm Dosing Pump
Water Treatment Electric Operated Diaphragm Discharge Pump

Water Treatment Electric Operated Diaphragm Discharge Pump
Automatic Solenoid Dosing pump with Smart Design

Automatic Solenoid Dosing pump with Smart Design
 
   


[ 返回产品型录 ]

Commerce 会员:
请登录您的帐号跟口令,系统将为您填入您的相关资料
 
 
帐号:
口令:
记住我的帐号
 
 
填写下列表格并寄送询问函.所有的询问信函将会自动寄发给你想联络的公司
主題
內容 ( 请勿输入公司名称、Email、电话、传真、网址 )
   

 


公司简介:

* 公司名称
*E-mail
*国家
*联络人
网址
*电话
- -
传真
- -
*邮递区号
*城市
*街道地址
*企业形态
批发商   出口商 进口商 制造商
大盘商 零售商  代理商 Retrofitter 使用者
其他, 请详细说明:
*安全口令
请输入所显示的安全口令


网站导览 l 隐私权政策 l 服务团队 l 合作提案 l 联络我们 l 帮帮我 l 广告刊登l  B2B商业伙伴
    .